Technical Analysis of Clean Air Conditioning Control System negative pressure clean room
The clean air conditioning control system negative pressure clean room is specifically applied to clean air conditioning systems in industries such as clean rooms, microelectronics factories, semiconductor factories, GMP, biopharmaceutical companies, and chemical clean rooms. It can achieve automatic adjustment of system temperature and humidity, pressure difference, dew point, air volume, and wind speed, as well as various safety protection, interlocking, energy-saving operation and other control functions. It maximizes the control and accuracy requirements of temperature and humidity, pressure difference in clean rooms, and provides a high cleanliness and low-energy consumption indoor environment for enterprise production processes.
Monitoring content
1. Adjust the valve opening;
2. Opening degree of air valve; 3. Filter pressure difference; 4. Supply air temperature and humidity;
5. Supply air speed; 6. Return air (indoor) temperature and humidity monitoring and constant temperature and humidity control (circulating unit); 7. Exhaust (indoor or supply) temperature and humidity monitoring and independent control of constant temperature and humidity (DC system); 8. System air volume and pressure control; 9. Summer/winter mode switching control; 10. Indoor pressure monitoring and control function; 11. System hardware fault self diagnosis function; 12. Start stop control of the air supply fan; 13. Automatic input function for disinfection and self-cleaning control process (proprietary function of pharmaceutical factory system); 14. Interlocking control between exhaust fan and supply fan (DC system); 15. Operation and fault status detection of air supply and exhaust fans; 16. Middle school efficiency filter pressure difference alarm; 17. Various electrical safety protection functions such as overcurrent and short circuit; 18. Accumulation of operating time and maintenance reminder function for vulnerable parts of the unit; 19. Fire signal interlocking control; 20. Interlocking control function between process exhaust, process dust removal equipment, air conditioning fresh air, and air supply system (exclusive function of pharmaceutical plant system). Multi unit surgical room temperature and humidity independent adjustment control; 21. Protection and control of air pressure difference in the supply fan; Product technical features: 1. Clean engineering mainly filters dust, bacteria, etc. in the air through the circulation of air volume, achieving the control of non biological particles and biological particles in the air, and achieving the standard of dust-free. Therefore, sufficient air volume is required to ensure the cleanliness of the indoor environment. The air volume of clean engineering is generally calculated based on the indoor air exchange rate, which is usually 10 times or even dozens of times, especially in one-way flow clean rooms where the air exchange rate reaches several hundred times the volume of the room. 2. Clean engineering generally requires at least primary, intermediate, and tertiary filters for filtration, and the combined resistance of these tertiary filters is about 700-800 Pa. Clean engineering generally uses centralized air supply and return to ensure the requirements of maintaining positive and negative pressure regulation in the clean room. Therefore, the pipeline resistance in the clean room is generally more than twice that of ordinary air conditioners. Therefore, the air handling unit in the clean room generally uses a rear curved wing fan or a shell free fan to achieve a sufficiently high return air pressure head. The lower the air leakage rate of the air handling unit used in clean engineering, the more energy is saved for customers and the lower the operating costs. The precision of temperature and humidity control in cleanrooms is to meet process requirements, such as in the manufacturing of certain electronic products where strict temperature and humidity control is required. In order to achieve constant temperature and humidity, it is required that clean engineering air handling units have at least cooling, heating, humidification, dehumidification and other functional sections, and require precise control methods; If the heat exchanger needs to use high-efficiency hydrophilic fins, and the water flow rate should be controlled by proportional integral, the humidification amount should also be adjusted by proportional integral or PID to achieve higher control accuracy. 4. Fully understand the purification needs of various industries, and based on the control requirements of the industry, integrate modern purification air conditioning technology, automatic control, and computer communication technology to measure, analyze, and control the operating energy consumption of refrigeration and air conditioning system equipment, providing a high-precision, low-energy constant temperature and humidity environment; Flexibly adopt optimal control strategies for different types of air conditioning systems and heat and humidity treatment schemes; Taking into account the operating environment of the system and maximizing the use of outdoor fresh air during transitional seasons to achieve energy-saving control of the system; Good coordination with rotary dehumidification system, fresh air pretreatment system, deep dehumidification and other air conditioning systems, providing reliable and high-precision control for low humidity environments; The controller, sensors, actuators, and electrical components have undergone strict testing and verification, using imported and nationally renowned brands to ensure system stability, reliability, high efficiency, and energy efficiency; Adopting an integrated design of strong and weak electricity, eliminating system interference, simplifying system wiring, ensuring stable system operation, and facilitating operation and maintenance; Adopting a touch screen based upper level human-machine interface for centralized management and simplified operation; Adopting the standard MODBUS RTU protocol and reserving network communication interfaces that support international mainstream communication protocols to enable connection with third-party systems such as DCS systems or negative pressure clean room
|
project |
negative pressure clean room | ||
|
air clean class |
Class 100000 ISO8 |
||
| air cleaning | H14 high effect air filter | ||
| air flow | 15000m3/H | ||
| control humidifier | 40% | ||
| control temperature | 22℃ | ||
| wall and ceiling | 50mm thickness PU sandwich panel | ||
| project standard | GMP | ||
| used for | plant drying room | ||