modular cleanroom systems
GMP modular cleanroom systems workshop is a type of purification workshop that is mandatory for industries such as food, pharmaceuticals, and health food, especially for industries like pharmaceuticals and health products that require the use of certified GMP workshops. GMP workshop is a type of dust-proof workshop. The walls and roof panels of the purification plant are generally made of 50mm thick sandwich color steel plates, which are characterized by beauty and strong rigidity. The curved corners, doors, window frames, etc. are generally made of special alumina profiles
GMP standards are a set of mandatory standards applicable to industries such as pharmaceuticals and food. Enterprises need to establish a set of operational standards in terms of raw materials, personnel, facilities and equipment, production processes, packaging and transportation, quality control, etc. to improve the hygiene environment of the enterprise.
Simply put, GMP requires production enterprises to have good production equipment, reasonable production processes, sound quality management, and strict testing systems to ensure that the quality of the final product (including food safety and hygiene) meets regulatory requirements
The walls and roof panels of the purification plant are generally made of 50mm thick sandwich color steel plates, which are characterized by beauty and strong rigidity. Curved corners, doors, window frames, etc. are generally made of specialized alumina profiles; The ground can use epoxy self leveling flooring or advanced wear-resistant plastic flooring. For those with anti-static requirements, anti-static types can be selected; The return air duct is made of hot-dip galvanized sheet and coated with flame-retardant PF foam plastic sheet with good purification and insulation effect; The high-efficiency air supply outlet is made of stainless steel frame, which is beautiful and clean. The perforated mesh plate is made of baked aluminum plate, which is rust free and dust-free, and suitable for cleaning.
In order to prevent cross contamination, the tools used to clean and purify the facilities in the MP workshop should be specialized according to the product characteristics, process requirements, and different levels of air cleanliness. Garbage should be placed in dust bags and taken out. The cleaning of GMP workshop must be carried out before commuting and after the completion of production process operations; Cleaning should be carried out during the operation of the air conditioning system in the purification workshop; After the cleaning work is completed, the purification air conditioning system should continue to operate until the specified cleanliness level is restored, and the start-up time is generally not less than the self purification time of the GMP workshop. The disinfectant used should be replaced regularly to prevent microbial resistance. When large objects are moved into the workshop, they should first be cleaned with a vacuum cleaner in a general environment, and then allowed to enter the purification workshop for further processing using a clean room vacuum cleaner or wiping method; During the shutdown of the GMP workshop purification system, it is not allowed to move large objects into the purification workshop.
GMP workshops modular cleanroom systems need to undergo disinfection and sterilization, which can be achieved through dry heat sterilization, moist heat sterilization, radiation sterilization, gas sterilization, or disinfectant sterilization. Now we introduce radiation sterilization, which is mainly suitable for sterilizing thermosensitive substances or products, but it must be proven that the radiation is harmless to the product. Ultraviolet radiation disinfection has a certain bactericidal effect, but there are many problems in its use. Factors such as the strength, cleanliness, environmental humidity, and distance of ultraviolet lamps can affect the disinfection effect. In addition, its disinfection effect is not high and it is not suitable for spaces with personnel activities and air flow. These reasons make ultraviolet disinfection not accepted by foreign GMP. UV sterilization requires long-term exposure to the exposed object. For indoor irradiation, when the sterilization rate is required to reach 99%, the irradiation dose for general bacteria is about 10000-300000 uw S/cm. A 15W ultraviolet lamp placed 2m above the ground, with an irradiation intensity of about 8uw/cm, needs to be irradiated for about 1 hour. During this 1 hour, the irradiated area cannot be entered, otherwise it will also damage human skin cells and have a significant carcinogenic effect.
|
project |
modular cleanroom systems | ||
|
air clean class |
Class 10000 ISO 7 |
||
| air cleaning | H14 high effect air filter | ||
| air flow | 10000m3/H | ||
| control humidifier | 45% | ||
| control temperature | 18℃ | ||
| wall and ceiling | 50mm thickness PU sandwich panel | ||
| project standard | GMP | ||
| used for | plant drying room | ||
Company profile




Hot Tags: modular cleanroom systems, China modular cleanroom systems manufacturers, suppliers, factory