Whether in the establishment stage or stable operation stage of the clean room, the inspection of the clean room is a necessary step. This includes temperature detection, humidity detection, pressure difference detection, noise detection, and dust particle concentration detection. Today, we will mainly introduce how to conduct dust particle detection.
Clean room dust particle detection is carried out through a dust particle counter, which measures the number of dust particles per unit volume of the clean room.After turning on the instrument, run it steadily for a period of time and follow the instructions to operate it. When collecting dust particles, it is necessary to maintain the same height, temperature, and pressure. The fewer personnel in the collection room is the better, with a maximum of two people. Do not make significant movements that disturb the air to avoid data errors.
Detection point:
|
Area/㎡ |
Cleanliness level |
||
|
100 |
10,000 |
100,000 |
|
|
< 10 |
2 ~ 3 |
2 |
2 |
|
≥ 10 ~< 20 |
4 |
2 |
2 |
|
≥ 20 ~< 40 |
8 |
2 |
2 |
|
≥ 40 ~< 100 |
16 |
4 |
2 |
|
≥ 100 ~< 200 |
40 |
10 |
3 |
|
≥ 200 ~< 400 |
80 |
20 |
6 |
|
≥ 400 ~< 1000 |
160 |
40 |
13 |
|
≥ 1000 ~< 2000 |
400 |
100 |
32 |
|
≥2000 |
800 |
200 |
63 |
Sampling volume:
|
Cleanliness level |
Sampling volume |
|
|
≥ 0. 5 um |
≥ 5 um |
|
|
100 |
5.66 |
- |
|
10,000 |
2.83 |
8.5 |
|
100,000 |
2.83 |
8.5 |
The number of measurement points varies depending on the cleanroom level and area. The higher cleanliness level, the more measurement points there are. The selection of measurement points also has requirements, usually collected uniformly on a horizontal plane at a height of 0.8m from the ground; When there are too many sampling points, the height from the ground can be expanded to 0.8m-1.5m, with multi-level collection and no less than 5 detection points per layer. When there are more than 5 detection points, they can also be detected at a distance of 0.8 meters to 1 meter from the ground Arrange within a 5m high area, but with no less than 5 points per layer. Even in small clean rooms or localized purification areas, there must be no less than 2 monitoring points.


Suzhou Pharma Machinery Co.,Ltd.
2025/02/07
Icey




