Laminar Flow Hood
Suzhou Pharma Machinery Co., Ltd. is a leading provider of turnkey projects for pharmaceutical, food, herbal, cosmetic, electronics, and chemical plants. Our extensive cleanroom expertise allows us to meet the precise needs of clients across diverse sectors, including medical, pharmaceutical, biotechnology, and cosmetics. In addition to turnkey projects, we also provide cleanroom equipment such as transfer windows, air showers, clean benches, and laminar flow hoods. We offer a comprehensive range of services for any cleanroom project you require.
Why Choose Us
Professional Certificates
We have obtained numerous authoritative certifications, including trademark registration, LED lamp certification, supercritical CO₂ extraction equipment certification, cleanroom system certification, filter material testing equipment certification, and SGS and CE certifications.
24-Hour Online Service
We provide all customers with 24/7 pre-sales and after-sales service. We have established a collaborative team of sales and technical engineers to ensure timely answers to customer questions and provide professional technical support.
Customized Services
Regardless of the scale of cleanroom projects, we offer comprehensive, customized solutions tailored to meet the specific requirements of various application scenarios and precisely address diverse customer needs.
Professional Team
We have comprehensive infrastructure and an experienced team of professionals with extensive expertise in various industries, including medical, pharmaceutical, biotechnology, and cosmetics. We provide efficient and systematic management and technical support in cleanroom-related areas.
Specification
|
Product name |
Laminar flow hood |
|
Cleanliness |
ISO5(Class100) |
|
Airflow direction |
Vertical air flow |
|
Average wind speed |
0.25-0.45 m/s |
|
Material |
Stainless Steel |
|
Noise |
≤62dB(A) |
|
Dimension |
1300*1100*750mm |
|
Purification area size |
1250*950mm |
|
HEPA filter size |
1000*500*90mm*2 |
|
Power |
AC 220V 50HZ 0.8KW |

● The laminar flow hood has low energy consumption and high static pressure and can be adjusted in multiple stages. The operatingcost of a laminar flow cabinet is low.
● The laminar flow hood is designed with a special flow channel and an equalizing system, which has the characteristics of low noiseand uniform air velocity.
● The laminar flow hood is light and adopts the hood-in installation method, which makes installation, flter replacement, andmaintenance more convenient.
Types of Laminar Flow Hood
Vertical Laminar Flow Hood
In a vertical laminar flow hood, clean air is directed from the top of the hood downward toward the work surface.
Horizontal Laminar Flow Hood
In a horizontal laminar flow hood, air enters from behind the workbench and is blown forward through HEPA filters, flowing horizontally over the workspace.
Laminar Flow Hood Components
The design of a laminar flow hood can vary, but all systems include these core components:
Fan
Draws air into the unit and pushes it through the filter.
01
Filter
This component traps airborne particles, usually a high-efficiency particulate air (HEPA) or an ultra-low penetration air (ULPA) filter.
02
Laminar Flow
The clean air moves in parallel lines at a uniform speed. In a horizontal laminar flow hood, the flow is from back to front, in a vertical laminar flow hood, it is from top to bottom.
03
Work Surface
The area where tasks requiring a clean environment take place.
04
Control System
This includes switches for operating the fan and lights, speed controls, and additional features.
05
● The principle of laminar flow hoodt is based on the laminar flow of air through the cabinet.
● The device works by the use of inwards flow of air through one or more HEPA filters to create a particulate-free environment.
● The air is taken through a filtration system and then exhausted across the work surface as a part of the laminar flow of the air.
● The air first passes through the filter pad or pre-filter that allows a streamline flow of air into the cabinet.
● The blower or fan directs the air towards the HEPA filters.
● The HEPA filters then trap the bacteria, fungi and other particulate materials so that the air moving out of it is particulate-free air.
● Some of the effluent air then passes through perforation present at the bottom rear end of the cabinet, but most of it passes over the working bench while coming out of the cabinet towards the face of the operator.
● The laminar flow hood is enclosed on the sides, and constant positive air pressure is maintained to prevent the intrusion of contaminated external air into the cabinet.

Hospitals
Laminar flow hoods are used in hospitals to protect patients from infection. They are often used in operating rooms and Intensive Care Units (ICUs).
Pharmaceutical industry
Laminar flow hoods are used in the pharmaceutical industry to protect drugs and chemicals from contamination. They are used in research and development laboratories.
Food industry
Laminar flow hoods are used in the food industry to protect food from contamination. They are regularly used in restaurants, grocery stores, and food processing plants.
Electronics industry
Laminar flow hoods are used in the electronics industry to protect electronic components from contamination. They are often used in manufacturing and assembly plants.
Cleanrooms
Laminar flow hoods are used in cleanrooms to protect sensitive equipment from contamination. They are often used in semiconductor fabrication facilities.
Precautions for Using Laminar Flow Hood
● Ensure that only one person is working inside the hood at a time.
● Before bringing any equipment into the hood, spray it with a decontaminant to prevent contamination in your workspace. Contamination during microbiological applications is your worst enemy.
● With any materials (e.g. reagents, consumables) if you suspect they are contaminated, throw them out and replace them.
● Always wear proper personal protective equipment (PPE), including a lab coat and gloves. You should change your gloves and other PPE immediately if you suspect they have become contaminated.
● Keep your head and shoulders outside of the workspace to reduce the risk of sample contamination.
● Do not work inside the hood when the UV light is switched on.
Our Service
7 days shipments
Fast production and most of the materials have stock in our warehouse, we can ship within 7 days after you put on order, except the special made air conditioner.
Happiness Design
Make you own design under our help with happiness and easily satisfy you.
"LEGO" installation
All the installation parts equipped with 3D video, "0" experience to finish by yourself.
Overseas standby
Overseas team is standby at any time for your service if you need our people for work
Bank credit service
We can supply max. 20% credit for clients without any special request to make you earn money then give back the investment.
24 hours on-line service
All of customer will enjoy 24 hours pre-sale and after sale online service, we build a discussing group that both salesman and engineer join us to answer your question and provide technical support.
Packaging and Shipping
|
Packaging |
Wooden box, PE film |
|
Transportation methods |
Road transport, rail transport, sea transport, air transport |
Video
Our Certificate





We're well-known as one of the leading laminar flow hood manufacturers and suppliers in China. If you're going to wholesale customized laminar flow hood at competitive price, welcome to get quotation from our factory.