Conditions For Achieving Cleanliness Level Requirements

Build a excellent clean room not only need good design and excellent product quality, but also air conditioning purification scheme, installation process, correct usage method and prefect maintenance scheme. Today, I will introduce the basic conditions for achieving cleanliness requirements.

1.Air supply cleanliness

In order to achieve the cleanliness of the incoming fresh air to meet the requirements, the key lies in the selection of filters. There are many different levels of air purification filters, and the filtering effects are also different. It is usually followed principles that high-performance filters are selected for high-level clean rooms and low-performance filters are selected for low-level clean rooms. In addition to the selection of filters, it is also necessary to pay attention to professional installation, do not damage the filters, and pay attention to checking the tightness during installation.
2. Airflow organization

Because the functions of clean rooms are different from those of ordinary rooms, the airflow operation is also different from that of ordinary air conditioners. It is necessary to prevent external polluted air from entering the clean room, prevent dust from being raised, and the airflow flows slowly and evenly, and the polluted air in the clean room must be discharged.
3. Air volume or wind speed

In order to keep the clean room at the required clean level, it must be constantly ventilated. The higher the clean level, the more ventilation is required. The appropriate air volume and wind speed should be set according to the room area, cleanliness requirements, number of people in the room, temperature and other conditions.
4. Pressure difference

Pressure difference is an indispensable condition to ensure the grade requirements of clean rooms. Air flow direction is controlled by pressure difference. Pressure difference is achieved by the air supply and exhaust volume of the purification system, which requires the clean room to have good airtightness. Regulations require that the pressure difference between the clean area and the non-clean area in cleanroom should not be less than 5Pa, and the pressure difference between the clean room interior and the clean room exterior should not be less than 10Pa.