1. Cleanliness control
Use HEPA filter or ULPA filter to ensure that the workshop meets the cleanliness level of ISO Class 5-8. Maintain a positive pressure state within the workshop to prevent external pollutants from entering. Design a reasonable airflow pattern to ensure smooth and uniform air flow in the work area.
2. Temperature and humidity management
Maintain a stable room temperature between 20°C and 25°C, as excessively high or low temperatures may affect battery performance and production processes. Control the relative humidity within the range of 20%-60% RH.
3. Explosion proof and fire prevention measures
Use explosion-proof electrical equipment in flammable and explosive environments. Install automatic sprinkler fire extinguishing systems, gas fire extinguishing devices, and manual fire extinguishers; Set up emergency evacuation routes and equip them with sufficient emergency lighting signs. Configure a gas detector to monitor the gas concentration in the workshop in real time. Once it exceeds the standard, immediately sound an alarm and take corresponding measures.



4. Static protection
Ensure that all metal objects are well grounded to reduce the risk of static electricity accumulation; Operators use personal protective equipment such as anti-static shoes, socks, wrist straps, etc. Install ion fans near critical processes to neutralize static charges.
5. Ventilation and air exchange
Provide sufficient fresh air supply to meet the breathing needs of personnel while diluting the concentration of harmful gases. For areas with harmful gases, exhaust gas collection and purification devices should be equipped to ensure emissions meet standards.
6. Noise control
Select low-noise equipment or take noise reduction measures to control the noise level in the workshop below 75dB (A).
7. Lighting conditions
Set appropriate illumination values according to the needs of different workstations. It is generally recommended that the office area should not be less than 300lx, the production line should not be less than 500lx, and the inspection area should not be less than 750lx. Priority should be given to LED lighting fixtures, as they have the advantages of energy saving, long lifespan, and no flicker, which are beneficial for improving work efficiency and visual comfort.
8. Action route planning
Plan a reasonable route, shorten the distance of material handling, and reduce the possibility of cross contamination through repeated personnel travel.
9. Emergency plan
Develop a comprehensive emergency plan for accidents, including procedures for handling situations such as fires, leaks, and poisoning; Organize regular drills to enhance employees' ability to respond to emergencies.
Suzhou Pharma Machinery Co.,Ltd.
2025/08/18