Why are there dry bulb temperature, wet bulb temperature, and dew point temperature for air? Let's understand this from the aspects of air conditioning humidification and dehumidification.

The ambient air we are in is all moist air, which is composed of dry air and water vapor. In order to more comprehensively and accurately describe the thermal and moisture characteristics of air from different perspectives, the air temperature is respectively defined with dry bulb temperature, wet bulb temperature, and dew point temperature to meet the practical needs of different fields.

1.Dry Bulb Temperature

The dry bulb temperature is the temperature directly measured by an ordinary thermometer in the air. It intuitively reflects the actual hot and cold degree of the air and is the temperature concept that people most often come into contact with and feel in daily life. For example, the weather temperature and indoor temperature we usually talk about all refer to the dry bulb temperature. In many engineering fields and scientific research, the dry bulb temperature is a basic parameter and basis. For instance, in architectural design, it is necessary to determine the thermal insulation measures of buildings according to the dry bulb temperature in different regions and calculate the heat load of buildings. In air conditioning design, the dry bulb temperature is also the main basis for determining the cooling capacity or heating capacity.

2.Wet Bulb Temperature

The wet bulb temperature is the air temperature when the water vapor in the air reaches saturation under the condition that there is no heat exchange between the air and the outside world and the moisture content is changed only through the evaporation or condensation of water. On the psychrometric chart, the "unsaturated" dry bulb temperature drops along the constant enthalpy line and intersects with the 100% relative humidity line, and the corresponding temperature is the "saturated" wet bulb temperature. The difference between the wet bulb temperature and the dry bulb temperature reflects the humidity condition of the air. The larger the difference, the more "unsaturated" the air is, so the faster the water vapor evaporates and the stronger the heat absorption capacity of the air. Conversely, the smaller the difference, the closer the air is to the saturated state and the higher the humidity.

The concept of wet bulb temperature corresponds to the "constant enthalpy humidification" process in air conditioning. When the supply air flows through the wet film humidifier of the air conditioning unit, the external water absorbs heat and evaporates into the air, increasing the water vapor content in the air, thus achieving humidification. During the humidification process, the air gains moisture and its moisture content increases, but the heat absorbed by the evaporation of water is taken from the air, causing the air temperature to drop. That is to say, the air gains latent heat but loses sensible heat, and the two are in balance and equal, so the enthalpy remains unchanged during the process, which is a constant enthalpy humidification process.

air handling unit

cleanroom ac

3.Dew Point Temperature

The dew point temperature is the temperature at which the air is cooled to the point where the water vapor reaches saturation and begins to condense into liquid water while keeping the moisture content unchanged. On the psychrometric chart, the "unsaturated" dry bulb temperature drops along the constant humidity line and intersects with the 100% relative humidity line, and the corresponding temperature is the "saturated" dew point temperature.

The concept of dew point temperature corresponds to the "cooling dehumidification" process in air conditioning. When the supply air flows through the surface air cooler of the air conditioning unit, since the water temperature in the surface air cooler is lower than the dew point temperature of the air, the supply air is cooled and dehumidified. The cooling dehumidification process is divided into two stages. Cooling from the dry bulb temperature to the dew point temperature is the "dry cooling" stage, during which only the temperature drops without dehumidification and there is no condensed water. Then comes the "wet cooling" stage, moving left along the saturated humidity line from the dew point. At this time, the main process is the condensation and precipitation of condensed water for dehumidification, accompanied by a small amount of temperature drop.

In practical applications, the dew point temperature is also often used to judge and control the risk of condensation. For example, in the air duct of an air conditioning system, if the air temperature drops below the dew point temperature, condensation will occur on the inner wall of the air duct, leading to problems such as water dripping and the growth of bacteria, which will affect the normal operation of the system and the indoor air quality. At this time, it is necessary to calculate and select appropriate thermal insulation materials and their thicknesses.

4.The Three Temperatures

The dry bulb temperature is the temperature of the "unsaturated" air that we come into contact with and feel in daily life and is the basic basis for refrigeration and heating calculations. The wet bulb temperature is the air temperature when it reaches "saturation" by relying on the increase of moisture without heat exchange with the outside world. The dew point temperature is the air temperature when it reaches "saturation" due to external cooling without moisture exchange with the outside world.

The dew point (Dew point), also known as the dew point temperature (Dew point temperature), in meteorology refers to: under the condition that the water vapor content in the air remains unchanged and the air pressure is kept constant, the temperature at which the air is cooled to reach saturation is called the dew point temperature, abbreviated as the dew point, and the unit is expressed in °C or °F. In fact, it is also the temperature at which water vapor and water reach an equilibrium state. The difference between the actual temperature (t) and the dew point temperature (Td) represents the degree to which the air is away from saturation. When t > Td, it indicates that the air is unsaturated; when t = Td, it indicates that the air is saturated; when t < Td, it indicates that the air is supersaturated.

Under the condition that the water vapor content in the air remains unchanged and the air pressure is kept constant, the temperature at which the air is cooled to reach saturation is called the dew point temperature, abbreviated as the dew point, and its unit is the same as that of the air temperature.

When the dew point drops below the freezing point, the water vapor precipitated from the air will not form liquid water but directly solidify into solid ice. Fine ice particles adhere to the surface of other objects to form frost. At this time, the dew point is also called the frost point. Generally, above 0°C is called the "dew point", and below 0°C is called the "frost point".

The dew point is related to another commonly used humidity index, relative humidity. The higher the relative humidity, the closer the dew point will be to the air temperature; when the relative humidity reaches 100%, the dew point is equal to the air temperature. When the dew point remains unchanged, the relative humidity is inversely proportional to the air temperature. Since the dew point is related to both the air temperature and the relative humidity, the dew point in nature will definitely change continuously.