There are many differences between Class 1000 cleanroom and Class 10000 cleanroom, among which the most crucial difference lies in the cleanliness level.
Due to the different cleanliness levels of the two, there is a direct difference in the number of air changes, leads to a different amount of dust particles that can be accommodated indoors. Correspondingly, the requirements for filtering dust particles are also different, ultimately reflected in various aspects such as air volume configuration, required equipment, and cost. Normally, the cleanliness level of a Class 1000 cleanroom is higher, which also means that its construction cost is relatively higher.
Specifically, the Class 1000 cleanroom has clear requirements for humidity control, which must be maintained within a range of 55±5%, and the number of dust particles with a particle size of 5 microns per cubic meter of air must be less than 50000. On the other hand, the measurement standard for a Class 10000 cleanroom is that the number of dust particles with a particle size of 0.5 microns per cubic meter of space should not exceed 10000; The total number of particles with a particle size greater than or equal to 0.5 microns shall not exceed 350000; the total number of particles with a particle size greater than or equal to 5 microns shall not exceed 2000.
The Class 10000 clean room has strict requirements for temperature and humidity. Usually, the winter temperature is controlled between 20-22℃, with an allowable fluctuation range of ±2℃; In summer, the temperature is controlled at 24-26℃, with a fluctuation range of ±2℃. In terms of humidity, the clean room maintains a humidity of 30-50% in winter and 50-70% in summer.