1. Classified by exhaust method:
It is divided into three types: upper exhaust type, lower exhaust type, and simultaneous upper and lower exhaust type.
To ensure uniform wind speed in the work area, a lower exhaust type should be used for cold process fume hoods, and an upper exhaust type should be used for hot process fume hoods. For processes with unstable heat generation, exhaust ports can be set up both above and below to adjust the ratio of upper and lower exhaust air volume according to the change in heat generation inside the cabinet, thereby obtaining uniform wind speed.
2. Classify by air intake method
1) Full exhaust fume hood:
The method of circulating indoor air inside the cabinet and then discharging it outside is called full exhaust, which is a widely used type.
2) Supplemental ventilation cabinet:
When the fume hood is installed in a room with heating or temperature and humidity control requirements, in order to save heating and air conditioning energy consumption, the method of taking supply air from the outside and circulating it inside the cabinet before discharging it outside is called a supplementary air fume hood.
3) Variable air volume fume hood:
A regular constant air volume system requires manual adjustment of the fixed blade air valve, adjusting the exhaust volume of the fume hood, and achieving the desired surface air velocity when the valve is adjusted to a certain angle. Variable air volume control is achieved by adjusting the sensor of the valve to change the air volume to a given surface wind speed. Of course, standard methods have low costs and variable air volume costs are high, making them suitable for high-precision applications.
3. Classify by usage status
It can be divided into integral lower open type, floor standing type, double-sided type, three sided glass type, tabletop type, integrated type, and specialized fume hoods designed according to different experimental needs for radioactive experiments, synthetic experiments, and perchloric acid experiments.
4. Classify according to the presence or absence of external pipelines
It can be divided into external ventilation cabinets and ductless ventilation cabinets.
External exhaust fume hood is a device that extracts toxic and harmful gases generated during experimental operations directly from the outside through an external pipeline.
A ductless fume hood directly adsorbs toxic and harmful gases generated during experimental operations using activated carbon filters. The main function of a fume hood is exhaust. In a chemical laboratory, various harmful gases, odors, moisture, as well as flammable, explosive, and corrosive substances are generated during experimental operations.
5. The layout principle is to protect the safety of users and prevent the spread of pollutants from the experiment to the laboratory. Ventilation cabinets should be installed near the pollution source.
Especially for most newly built laboratories, air conditioning is required, so the number of fume hoods to be used should be included in the air conditioning system plan during the preliminary design stage of the building.
Considering the improvement of laboratory environment, labor hygiene conditions, and work efficiency, the number of fume hoods will increase, and their ancillary facilities such as ventilation ducts, piping, wiring, and exhaust will become issues that need to be addressed in laboratory construction design.
The maximum function of a fume hood is to exhaust harmful gases during experiments, protect the health of experimenters, and have high safety and superior operability. The fume hood should have the following functions:
(1) Release function: It should have the ability to discharge harmful gases generated in the laboratory outside.
(2) Non backflow function: The function of generating airflow to prevent harmful gases from flowing back into the room from the inside of the fume hood.
(3) Isolation function: Equipped with non sliding glass windows to separate the inside and outside of the fume hood.
(4) Control wind speed function: To prevent harmful gases from escaping from the fume hood, a certain suction speed is required.
(5) Heat resistance and acid alkali corrosion resistance: Some fume hoods require the installation of electric furnaces, while others produce large amounts of toxic and harmful gases such as acid and alkali, which have strong corrosiveness. The countertop, lining plate, side plate, and selected water and air nozzles of the fume hood should have anti-corrosion function. In laboratory operations, safety is the primary purpose of using fume hoods, whose function is to ensure the safety of users and prevent pollution to the surrounding environment. Ventilation usually uses the following techniques to improve safety: 1. Adopting a single seam exhaust structure to effectively discharge harmful gases. 2. Streamlined handle, with a gap between the handle and the glass. Due to the rotating flow of air on the table, effective air intake is ensured from the surface. 3. Set up anti drop pins for windows. In case the steel wire rope falls off and the glass window accidentally falls, the anti drop pin will catch it and prevent injury to personnel. 6. The glass window adopts tempered glass, so even if the glass is accidentally damaged or exploded, there will be no injury accidents. 5. Ventilation holes are installed on the upper part of the fume hood to allow air to enter even if the glass window is closed, avoiding the generation of greater negative pressure. 6. The shell of the fume hood is made of metal material, which is fire-resistant and non combustible. The inner cavity is made of flame-retardant or non combustible materials such as anti double special plates and stainless steel plates, and the tabletop is made of solid core physical and chemical plates or stainless steel plates that are acid and alkali resistant, heat-resistant, and flame-retardant. 7. The effective height of the glass window is 800mm, the inner cavity is 1200mm, and the tabletop height is 800mm, which conforms to ergonomics, is easy to operate, has a large space for use, and improves safety. 8. The water nozzle and air nozzle can be operated remotely by a handle outside the cabinet, which is more convenient and safe than direct manual operation. Attention: Before starting the experiment, it is necessary to confirm that the fume hood should be in operation before conducting experimental operations. Before the experiment is completed, the ventilation fan must continue to run for at least 5 minutes to remove any residual gas from the pipeline. It is also possible to consider installing an exhaust time delay device to ensure that the ventilation fan operates in a delayed manner. During the experiment, do not place any equipment within 150mm of the glass window. Large experimental equipment should have sufficient space and should not affect the flow of air. The front window should be closed as much as possible for use.
7. The use and maintenance of fume hoods in laboratories are closely related not only to correct design, but also to reasonable use and maintenance. Therefore, the following points should be noted: (1) During the experimental process, experimental devices that produce harmful substances should be placed in a place where the operating port of the fume hood is greater than 150mm to prevent harmful substances from overflowing; (2) The experimental device of the fume hood should not obstruct the exhaust slit; (3) After the experiment is completed, the fan should not be turned off immediately. It should be turned off after 3-5 minutes; (4) Ventilation cabinets should not be used as storage cabinets; (5) The interior of the fume hood should be kept clean and sealed regularly, and thoroughly cleaned and swept. If there is any damage, it should be repaired in a timely manner; (6) Ventilation fans, ducts, and related accessories should be regularly inspected. (7) At regular intervals, the fume hood must be measured and adjusted; Operate the fume hood under the designed conditions; (8) The temperature inside the fume hood, such as electric furnaces with high wattage, should be padded with blocks and plates, and should not be stored or opened for a long time to avoid affecting the use of the fume hood.